Hello,
Last night at 00:24 a node gave the error "Hardware health monitoring on (server name) is undefined." but there wasn't any alert triggered.
I have made an alert so that our technician will receive the alert in the morning. Can you please tel me if I have built the alert the correct way:
"Execute program : powershell.exe -ExecutionPolicy Bypass "C:\Alert_Scripts\SMS_Alert.ps1" "Helpdesk" 'Alert: ${NodeName} on ${IP_Address} is ${Status} (more than 10 minutes).'
On Sunday from 07:00 to 22:00"
I am asking this because I have built this alert for more nodes and every time a node is unreachable the alert works fine even at 07:01. It seems that there is something wrong with how I am defining this. Can somebody help me with this one or give me some advice how tho buildt this one so that I will get an alert?
I was thinking of changing the trigger from Node status is equal to down to Node status is not equal to up.
Thanks in advance!